Yeungnam Univ J Med Search

CLOSE


Yeungnam Univ J Med > Volume 10(2); 1993 > Article
Yeungnam University Journal of Medicine 1993;10(2):409-416.
DOI: https://doi.org/10.12701/yujm.1993.10.2.409    Published online December 31, 1993.
Comparison study of AAS and ISE method in the lithium analysis of serum and urine.
Soo In Lee, Chae Hoon Lee, Kyung Dong Kim, Chung Sook Kim
Abstract
In the method for lithium (Li) analysis, flame emission photometry and atomic absorption spectrophotometry (AAS) have been used most frequently. In addition, lithium can be analyzed by ion-selective electrode (ISE) or fluorscence polarization immunoassay. We evaluated the comparison between AAS method based on the principle of absorption of light at 670.8 nm by Li and ISE method based on the principle of voliage difference generated by Li in contact with lithium ionophore. We compared with those obtained by AAS (AA/AE Spectrophotometer 551, Instrumentation Laboratory Co.) and ISE (SYNCHRON EL-ISE, Beckman Co.) in the serum and urine of 6 pati,,:nts- and evaluated time-related changes of serum lithium concentration after dosing in both methods. The results are summarized-as follows: 1. In within-run precision study for lithium concentration, coefficient variations (CVs, %) ranged from 1.34 to 2.17 for AAS and from 0.34 to 0.85 for ISE method. In between-run precision study for lithium concentration, CVs ranged from 1.23 to 1.72 for AAS and from 0.61 to 1.38 for ISE method. 2. The correlation study between AAS and ISE method resulted in Y= 0.946X+ 0.137 (N = 32, r= 0. 933, X= AAS, Y= ISE) for serum lithium and Y= 1. 092X+ 0. 977 (N= 28, r= 0.943, X= AAS, Y= ISE) for urine lithium. 3. Time-related changes of serum lithium concentration in both AAS and ISE method resulted in peak serum levels about 2 hours after dosing and then rapidly decreased after the peak serum level and finally arrived at nearly initial levels about 9 hours after dosing. 4. The reference range of serum lithium was found as undetectable level for both AAS and ISE method and the reference range of urine lithium to the urine creatinine was 0 0.00014 mmol/mg(mean 0.00002 mmol/mg) for AAS method.
TOOLS
Share :
Facebook Twitter Linked In Google+ Line it
METRICS Graph View
  • 0 Crossref
  •    
  • 71 View
  • 0 Download
Related articles in Yeungnam Univ J Med


ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
170 Hyeonchung-ro, Nam-gu, Daegu 42415, Korea
Tel: +82-53-640-6832    Fax: +82-53-651-0394    E-mail: yujm@yu.ac.kr                

Copyright © 2019 by Yeungnam University College of Medicine. All rights reserved.

Developed in M2community

Close layer
prev next