The Treatment of Giant Middle Artery Aneurysm with MDS Coil: Case Report.
Gwang Shik Choi, Sung Ho Kim, Jung Ho Bae, O Lyong Kim, Byung Youn Choi, Soo Ho Cho, Woo Mok Byun
1Department of Neurosurgery College of Medicine, Yeungnam University Taegu, Korea.
2Department of Diagnostic Radiology College of Medicine, Yeungnam University Taegu, Korea.
Abstract
A 14-year old boy was admitted with stuporous mentality. CT scan, MRI and cerebral angiogram revealed SAH and a giant aneurysm of right middle cerebral artery(4x5x5.3cm). To minimize surgical risk, endovascular treatment was done with MDS(mechanical detachable system)-spiral coil. Follow up MRI showed intraluminal thrombus formation of the aneurysm.
Key Words: Giant aneurysm, Endovascular treatment, MDS-coil, Intraluminal thrombus